In the Contact node, you define the mechanical and numerical properties for a set of contact pairs in a contact analysis. Use it for modeling structural contact and multiphysics contact. In the latter case, you will also need to add corresponding pair conditions in the other participating physics interfaces.
In the contact pair, the destination side selection must be part of the physics interface in which you add the Contact node. The source side selection can be any kind of meshed object, but if it is part of the current physics interface, more options are made available.
|
The Slip Velocity and Wear subnodes are only available in the Solid Mechanics and Multibody Dynamics interfaces.
|
Do not select the same contact pair in more than one Contact node. Doing so may produce error messages or unpredictable results.
The Contact node is only available with some COMSOL products (see
https://www.comsol.com/products/specifications/).
|
When a Contact node is present in your model, all studies are geometrically nonlinear. The Include geometric nonlinearity check box on the study step Settings window is selected and cannot be cleared.
For a Solid Mechanics or Layered Shell interface, a Contact node will override all previous nodes in the Model Builder tree sharing the same boundary selections. If you want to add a load (such as the pressure of a surrounding fluid), the best way of doing that is to select a Boundary Load from the Fallback Features of the Contact node. Such a load will then act only on the portions of the boundaries not being in contact. No fallback features are available in the Layered Shell interface.
If an ordinary Boundary Load node is added after the Contact node in the Model Tree, it will contribute to the load on the boundaries, but without taking the contact state into account.
|
If the source side of the contact pair is not part of the current physics interface, select Source external to current physics. When selected, only the location of the mesh on the source side is taken into account when evaluating the contact.
|
If Source external to current physics is selected and the source selection intersects with the physics selection, the warning “ Source boundary internal to the current physics detected, even though the ‘Source external to current physics’ check box is selected.” is displayed. If you are using a Shell, Layered Shell or Membrane interface on the source boundary, this situation means that any offset or thickness properties given on that selection is ignored by the contact.
The opposite situation, when the source boundary selection is not within the current physics interface, and Source external to current physics is not selected, is also problematic. That could cause some variables to become undefined. In this case, the following error is thrown: “ Source boundary external to the current physics detected, but the 'Source external to current physics' check box is not selected.” If the source selection contains boundaries which are both external and internal to the current physics, an error is always thrown.
|
When Contact is used in a Shell, Layered Shell, and Membrane interface, settings that control which side of the boundary that can come into contact are also made available.
For Contact surface, destination and
Contact surface, source, select
Top or
Bottom. The top side is the one with an outward pointing normal vector.
Select the algorithm used for computing the contact, Penalty (default);
Penalty, dynamic;
Augmented Lagrangian; or
Augmented Lagrangian, dynamic. The augmented Lagrangian method is in general more accurate than the penalty method, but also more expensive in terms of computer resources.
When Augmented Lagrangian is selected, it is also possible to choose
Solution method—
Segregated (default) or
Fully coupled. This setting affects how the default solver suggestion is set up when generating a new solver sequence, as well as some variable definitions and equations.
The Penalty, dynamic; and
Augmented Lagrangian, dynamic formulations are intended for use in time-dependent studies to model dynamics contact, such as soft impact type events.
Select the type of Penalty factor control —
Automatic;
Automatic, soft;
Manual tuning;
Nonlinear; or
User defined.
•
|
Automatic and Automatic, soft provide predefined values for the penalty factor multiplier fp. The Automatic, soft is mainly intended for bending dominated problems, typically encountered when using contact with the Shell interface.
|
•
|
For Manual Tuning, enter a Penalty factor multiplier fp. The default value is 1, which corresponds to the Automatic option.
|
•
|
For Nonlinear, enter an Initial penalty factor multiplier fp,init and a Final penalty factor multiplier fp,fin. Also enter a value for the Transition gap, gn,tr to control when to switch between the initial and final penalty factors. The default value is <phys>.hmin_dst.*1e-3.
|
•
|
For User defined, enter a Contact pressure penalty factor pn. The default value is <phys>.<contact_tag>.E_char/<phys>.hmin_dst. The variable E_char contains the value given as characteristic stiffness, and hmin_dst is the minimum element size on the destination selection.
|
Click to select Offset penalty function if you want the contact pressure to be nonzero when the gap is zero. In that case, also enter a value for the
Contact pressure at zero gap T0. Through this option, you can to some extent compensate for the overclosure that is inherent to the penalty method if you know an approximate value of the expected contact pressure.
Select the type of Penalty factor control —
Automatic;
Automatic, soft;
Manual tuning;
Nonlinear;
Viscous only; or
User defined. The settings are the same as for the standard penalty method, except for the
Viscous only option. By selecting
Viscous only, the stiffness terms of the penalty contact are omitted from the formulation.
Select the type of Viscous penalty factor control —
Automatic or
User defined. For
Automatic, enter a value for the
Characteristic time τn. This value can be used as a multiplier for the viscous penalty factor, but should as a rule-of-thumb be in the same order of magnitude as the duration of the contact event. When
User defined is selected, enter the
Viscous contact pressure penalty factor pnv. The default value is
(<phys>.<contact_tag>.E_char/<phys>.hmin_dst)*1[ms]. The variable
E_char contains the value given as characteristic stiffness, and
hmin_dst is the minimum element size on the destination selection.
Select the type of Penalty factor control —
Preset (default),
Manual tuning, or
User defined. The settings give access to an increasing level of detailed control of the penalty factor, and are available when
Solution method is set to
Segregated.
If you select Preset, you have the options to select
Tuned for to be
Stability (default),
Speed, or
Bending. If the contact boundaries move toward each other, so that large overclosures can be expected in the initial outer iterations, then
Stability is the better choice since it relaxes the penalty factor during the first iterations. In many models, where the contact state does not change much, using
Speed gives significant performance improvements. The
Bending option provides a low penalty factor equal to the one used for the first iterations when using
Stability. This option thus provides a conservative algorithm that can be particularly useful for problems dominated by bending. However, it might require many iterations to reach convergence.
The Penalty factor control selection
Manual tuning gives you access to a number of detailed settings for the penalty factor.
Enter a Penalty factor multiplier fp. The default value is 1. From
Use relaxation, select
Always (default),
Never, or
Conditional. When using relaxation, the penalty factor is decreased during the first outer iterations in each parameter or time step. The purpose is to avoid large residuals in the case of a large initial overclosure between the contacting boundaries.
If relaxation is used, enter the Initial Relaxation Factor ri. The default is 0.005. This factor multiplies the penalty factor in the first outer iteration. Enter
Number of iterations with relaxation Nr. The default value is 4. The penalty factor is gradually increased up to its full value, which is used in the outer iteration after the one where the specified number of iterations with relaxation have been reached.
If Use relaxation is set to
Conditional, enter a
Suppression criterion. The default is 0, which means that the relaxation is used for all parameter or time steps. This is a Boolean expression which, when fulfilled, suppresses the relaxation. If you, for example, know that your problem needs relaxation only during the initial phase of the solution, enter an expression like
load_parameter>0.1. It is also possible to use expressions based on the solution, for example
abs(solid.cnt1.gap)<0.05*h. This expression is true when the gap or overclosure is small compared to the mesh size. It could be taken as an indication that the contact problem is almost converged, and thus not in need of any relaxation of the penalty factor.
Using the Penalty factor control selection
User defined gives you the possibility to enter an explicit expression for penalty factor. Enter the
Contact pressure penalty factor pn. The default is
(min(1e-3*(5^niterCMP,1))*<phys>.<contact_tag>.E_char)/<phys>.hmin_dst. The default value causes the penalty factor to be increased during the outer iterations and takes material stiffness and element size at the contact surface into account. The variable
E_char contains the value given as characteristic stiffness, and
hmin_dst is the minimum element size on the destination selection.
|
The default values when Manual tuning is selected corresponds to the default expression when User defined is selected. The same expression is also used internally when Preset is used with the Stability option.
|
Select the type of Penalty factor control —
Automatic (default),
Manual tuning, or
User defined. These settings are available when
Solution method is set to
Fully Coupled.
•
|
For Manual Tuning, enter a Penalty factor multiplier fp. The default value is 1, which corresponds to the Automatic option.
|
•
|
For User defined, enter a Contact pressure penalty factor pn. The default value is <phys>.<contact_tag>.E_char/<phys>.hmin_dst. The variable E_char contains the value given as characteristic stiffness, and hmin_dst is the minimum element size on the destination selection.
|
Select the type of Viscous penalty factor control —
Preset (default),
Manual tuning, or
User defined. The settings give access to an increasing level of detailed control of the penalty factor.
When Preset or
Manual Tuning is selected, enter a value for the
Characteristic time τn. This value can be used as a multiplier for the viscous penalty factor, but should as a rule-of-thumb be in the same order of magnitude as the duration of the contact event. The same settings as for the segregated augmented Lagrangian method are available for the
Preset and
Manual Tuning options. However, the default is to use no relaxation when the
Augmented Lagrangian, dynamic method is used.
Using the Penalty factor control selection
User defined gives you the possibility to enter an explicit expression for penalty factor. Enter the
Viscous contact pressure penalty factor pnv. The default value is
(<phys>.<contact_tag>.E_char/<phys>.hmin_dst)*1[ms]. The variable
E_char contains the value given as characteristic stiffness, and
hmin_dst is the minimum element size on the destination selection.
This section is only available when Formulation is
Augmented Lagrangian or
Augmented Lagrangian, dynamic. Select the
Trigger cutback check box to enable additional control over solver cutbacks in a time-dependent study or a stationary study with an auxiliary sweep. Enter a logical expression for
Cutback criterion. When this expression evaluates to a nonzero value, the iterations are immediately terminated, and the solver tries to use a smaller value of the time or parameter. You can use this setting to avoid that the solver spends many iterations trying to recover from an unphysical state. As an example, if you know that the destination boundary is confined so that it will not move more than 1 mm anywhere, an entry like
solid.disp > 5[mm] can be useful, since it is unlikely that a displacement of this size should appear during a successful iteration history.
|
In the COMSOL Multiphysics Reference Manual:
|
Enter a value or expression for Offset from geometric destination surface doffset,d. The offset is subtracted from the gap in the normal direction of the destination surface.
Enter a value or expression for Offset from geometric source surface doffset,s. The offset is subtracted from the gap in the normal direction of the source surface.
Select Force zero initial gap to compensate for any difference caused by irregularities in geometry or mesh when the two contacting boundaries should exactly coincide in the initial state. Gaps smaller than the tolerance
Δgap are adjusted to be zero before any offset is added. By default,
Δgap is set to
Inf, meaning that all gaps detected are adjusted to be zero.
|
When combined with Force zero initial gap, the offset will be exact in the sense that it is not affected by mesh irregularities.
The adjustment made by Force zero initial gap does not move any nodes in the mesh. Effectively, it adds an extra hidden offset, which compensates for the initial distance between source and destination boundaries.
|
This section is only available when Formulation is
Augmented Lagrangian or
Augmented Lagrangian, dynamic. In the augmented Lagrangian method, the contact pressure is introduced as an extra dependent variable on the destination boundaries. Enter a value for
Contact pressure Tn to supply an initial value for the contact pressure.
To display this section, click the Show More Options button (
) and select
Advanced Physics Options in the
Show More Options dialog box.
This section is only available when Formulation is
Augmented Lagrangian or
Augmented Lagrangian, dynamic. In the augmented Lagrangian method, the contact pressure is introduced as an extra dependent variable on the destination boundaries. You can modify the shape function type and order of this field. The default is to always use a liner shape function order for the contact pressure, but using a higher order can improve the accuracy of the contact condition. A value up to the discretization order of the displacement field is allowed. This setting also affects the shape function for dependent variables added by any subnode added to the
Contact node.
To change the discretization, select Shape function type —
Lagrange or
Nodal serendipity.
•
|
For the Lagrange shape-function type, select Element order — Linear, Quadratic, Cubic, Quartic, or (in 2D) Quintic.
|
•
|
For the Nodal serendipity shape-function type, select Element order — Quadratic, Cubic, or Quartic. The Nodal serendipity option is not available when the order of the displacement field is linear.
|
The lumped solver used for the segregated augmented Lagrangian method is only optimal when the shape function order is Linear, otherwise use a standard segregated step instead. The proper solver sequence is set up when adding a new default solver.
To display this section, click the Show More Options button (
) and select
Advanced Physics Options in the
Show More Options dialog box.
|
•
|
The Integration order both affects the numerical integration of the contact weak contributions and the number of state variables used when, for example, computing friction forces.
|
|
To display this section, click the Show More Options button (
) and select
Advanced Physics Options in the
Show More Options dialog box.
Enter a Characteristic stiffness Echar. The default is
<phys>.Eequ, the equivalent Young’s modulus as defined by most material models. The characteristic stiffness (stored in a variable named
<phys>.<contact_tag>.E_char) is used in expressions for the default penalty factors for both the penalty and the augmented Lagrangian methods. The characteristic stiffness should be representative for the stiffness of the destination domain material in a direction normal to the boundary. You may for example need to adjust the default value in for the following cases:
•
|
The variable <phys>.Eequ is not defined by the material. This is the case for some user-defined materials.
|
In some cases, it is not desirable to include reaction forces from all physics when setting up the variational term of the contact weak contributions. When Fields excluded from variation is set to
Automatic, variations are taken with respect all fields expect when a
Wear subnode is added. If a
Wear subnode is active and uses a
Deformed geometry formulation, variations with respect to the material mesh displacement field is excluded in all weak equations added by
Contact and its subnodes. By setting
Fields excluded from variation to
Manual, it is possible to exclude variations with respect to any field present in the model. When
Manual is selected
, enter a comma separated list of field names to exclude. By default, the input field is populated with
material.disp, which exclude variations with respect to material mesh displacement field added by the deformed geometry functionality.
Select Add contact status to solver log to get printouts about the change in the contact state in the solver log window. Doing so will add internal dependent variables used for tracking the contact state on the destination boundaries.
The Penalty, dynamic and
Augmented Lagrangian, dynamic are dissipative formulations. When either of these are selected in the Contact Method section, select
Compute viscous contact dissipation to compute and store to the energy dissipated by the viscous pressure contact. This adds one extra dependent variable and an extra distributed ODE.
Physics tab with Solid Mechanics,
Layered Shell,
Shell,
Membrane, or
Multibody Dynamics selected: