When the Smith-Watson-Topper (SWT) Model, the
Wang-Brown Model or the
Fatemi-Socie Model is evaluated, the computed number of cycles to failure is limited. For low loads, when the number of cycles to failure becomes very large, the
Cycle cutoff parameter,
Ncut, provides an upper bound for the value of
ctf. If the load is so high that the computed number of cycles is less than
1, the value of
ctf is set to
0.5.