The Slit, Circular duct, Rectangular duct, and Equilateral triangular duct models are applicable as long as the cross-section dimension is much smaller than the wavelength and the boundary layer thickness is smaller than the wavelength. The cross-section parameter can be a slowly varying function of space. These are known as a low reduced frequency (LRF) model.
|
•
|
•
|
•
|
For Slit enter the slit Height h (SI unit: m). Use this model in narrow slit domains to include the damping and attenuation that occurs here because of the losses in the viscous and thermal boundary layer.
|
•
|
For Circular duct enter the duct Radius a (SI unit: m). This model is useful for modeling the damping and attenuation that occurs when acoustic waves propagate in all tubing systems of small cross-section dimensions.
|
•
|
For Rectangular duct enter the duct Side lengths W and H (SI unit: m). Use this model for waveguides and ducts with a rectangular cross section. Also see Advanced Physics Options for additional settings.
|
•
|
For Equilateral triangular duct enter the duct Side length d (SI unit: m). Use this model for waveguides and ducts with an equilateral triangular cross section.
|
To determine the complex propagation constants for a waveguide, of arbitrary cross section, use The Thermoviscous Acoustics, Boundary Mode Interface. Apply it on the cross-section geometry of the waveguide. The interface solves for the propagating modes and includes all losses in detail. The complex wave number kc is then given by the plane wave mode solved for. This is the variable tabm.kn. The predefined variable tabm.Zc gives the (lumped) specific characteristic complex impedance Zc. Search for the mode nearest to the (lossless) plane wave mode.
|
•
|
Speed of sound c (SI unit: m/s)
|
•
|
•
|
Ratio of specific heats γ (SI unit: 1). In many liquids the value of γ is close to 1, the exact value can be derived from the expression where the (isobaric) coefficient of thermal expansion αp and the isothermal compressibility βT is used.
|
•
|
Dynamic viscosity μ (SI unit: Pa·s)
|
•
|
•
|
Thermal conductivity k (SI unit: W/(m·K))
|
|
The Narrow Region Acoustics models are so-called equivalent fluid models that have a nontrivial (nonlinear) dependency on the frequency. This means that performing an eigenfrequency analysis should be considered carefully, see Eigenfrequency Study. Moreover, the linearization process (linearization with respect to the frequency) of the underlying mathematical models can cause numerical problems (an error message is thrown). For the Rectangular duct one remedy is to decrease the number of terms used in the sum, for the Circular duct it can be necessary to switch to another model, like the Very narrow circular duct (isothermal).
|