Brownian Force
The Brownian Force feature adds a Brownian force term Fb (SI unit: N) to the total force on the particles:
(5-14)
where
Δt (SI unit: s) is the time step taken by the solver
rp (SI unit: m) is the particle radius
T (SI unit: K) is the absolute fluid temperature
μ (SI unit: Pa·s) is the fluid dynamic viscosity,
kB = 1.380649 × 1023 J/K is the Boltzmann constant, and
ζ (dimensionless) is a normally distributed random number with a mean of zero and unit standard deviation.
As explained in Ref. 25, independent values for ζ are chosen in all directions. A different value of ζ is created for each particle, at each time step for each component of the Brownian force. The Brownian force leads to spreading of particles from regions of high particle density to low density.