For Floquet periodicity, also known as Bloch periodicity, enter a k-vector for Floquet periodicity kF (SI unit: rad/m) for the x, y, and z coordinates (3D components), the r and z coordinates (2D axisymmetric components), or x and y coordinates (2D components).
|
•
|
For Cyclic symmetry select a Sector angle: Automatic (the default) or User defined. For User defined enter a value for θS (SI unit: rad). Enter an Azimuthal mode number m (dimensionless).
|
To optimize the performance of the Floquet periodicity and the Cyclic symmetry conditions, it is recommended that the source and destination meshes are identical. This can be achieved by first meshing the source boundary or edge and then copying the mesh to the destination boundary or edge. When the Periodic Condition stretches across regions with a mix of default material models, PMLs, background pressure fields, or background acoustic fields, it is recommended to add one Periodic Condition for each set of such boundaries.
|
The Porous Absorber model uses Floquet periodic boundary conditions to model an infinite porous absorber used for sound proofing. The Application Library path: Acoustics_Module/Building_and_Room_Acoustics/porous_absorber
|
|