true | false
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
none | dataset name
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
How to input the solution to use. manual indicates that solnum is used. manualindices indicates that solnumindices is used. interp indicates that t is used.
|
|||
The times to use, for transient levels. Available when data is not none and the underlying data is transient.
|
|||
upperright | middleright | lowerright | upperleft | middleleft | lowerleft | middleright | center | middleleft | manual
|
The position of the legends for all plots in this group. Choose manual to specify the exact position.
|
||
All solutions on all levels
|
|||
An alternative way to specify the solutions to use, allowing you to enter, for example, range(1,1,20). Applicable when looplevelinput is manualindices on a level.
|
|||
all on all levels
|
How to input the solution to use, per level. manual on a level indicates that looplevel is used on that level. manualindices on a level indicates that looplevelindices is used on that level. interp on a level indicates that interp is used on that level.
|
||
on | off
|
|||
How to input the outer solutions to use. Applicable only for parametric sweep models. manual indicates that outersolnum is used. manualindices indicates that outersolnumindices is used.
|
|||
An alternative way to specify the outer solutions to use, allowing you to enter, for example, range(1,1,20). Applicable when outerinput is manualindices.
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
An alternative way to specify the solutions to use, allowing you to enter, for example, range(1,1,20). Applicable when innerinput is manualindices.
|
|||
solnum | solutioninfo
|
|||
true | false
|
|||
on | off
|
|||
on | off
|
|||
true | false
|
|||
true | false
|
|||
true | false
|
|||
The number of decimals for numerical values in the title when titlenumberformat is stopwatch or stopwatchsci.
|
|||
The number of exponent digits (1–3) for numerical values in the title when titlenumberformat is stopwatchsci.
|
|||
true | false
|
|||
The precision for numerical values in the title when titlenumberformat is auto, engineering, or scientific.
|
|||
true | false
|
|||
auto, if the title should be computed automatically. custom, if the title should be computed automatically, but customized. label, if the title should be the plot group’s label. manual, if the manual title should be used (the title property). none, if no title should be displayed.
|
|||
true | false
|
|||
on | off
|
Whether the title contribution of plots in this group should contain the type when titletype is custom.
|
||
on | off
|
Whether the title contribution of plots in this group should contain the unit when titletype is custom.
|
||
on | off
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
The window where the plot group is displayed. When plotting on a graphics server, graphics is equivalent to new.
|
|||
on | off
|
on | off
|
|||
on | off
|
|||
on | off
|
|||
{1,1,1} or last used edgecolor
|
|||
none | dataset name
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
Time corresponding to last selected solnum for transient levels
|
The time to use, for transient levels. Available when data is not none and the underlying data is transient.
|
||
on | off
|
|||
on | off
|
|||
on | off
|
|||
The index of the solution to use, per level, or interp, but only for transient solutions. Available when data is not none and the underlying data has multiple solutions.
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
|||
solnum | solutioninfo
|
|||
on | off
|
|||
true | false
|
|||
on | off
|
|||
true | false
|
|||
auto, if the title should be computed automatically. custom, if the title should be computed automatically, but customized. label, if the title should be the plot group’s label. manual, if the manual title should be used (the title property). none, if no title should be displayed.
|
|||
on | off
|
Whether the title contribution of plots in this group should contain the type when titletype is custom.
|
||
on | off
|
Whether the title contribution of plots in this group should contain the unit when titletype is custom.
|
||
auto | view name
|
The view settings to use when displaying this plot group. auto indicates that the view is selected automatically, or be created if there is none. Typically geometry-based datasets such as solution or mesh datasets use the current geometry view.
|
||
The window where the plot group is displayed. When plotting on a graphics server, graphics is equivalent to new.
|
|||
on | off
|
|||
on | off
|
on if a manual x-axis label should be used, off if it should be computed automatically. Available for 2D plot groups.
|
||
on | off
|
on if a manual y-axis label should be used, off if it should be computed automatically. Available for 2D plot groups.
|