Solid
This node uses this version of the heat equation to model heat transfer in solids:
(6-15)
with the following material properties, fields, and sources:
ρ (SI unit: kg/m3) is the solid density.
Cp (SI unit: J/(kg·K)) is the solid heat capacity at constant pressure.
k (SI unit: W/(m·K)) is the solid thermal conductivity (a scalar or a tensor if the thermal conductivity is anisotropic).
u (SI unit: m/s) is the velocity field defined by the Translational Motion subnode when parts of the model are moving in the material frame.
Q (SI unit: W/m3) is the heat source (or sink). Add one or several heat sources as separate physics features. See Heat Source node and Thermoelastic Damping subnode for example.
For a steady-state problem the temperature does not change with time and the first term disappears.
Model Input
This section has fields and values that are inputs to expressions that define material properties. If such user-defined property groups are added, the model inputs appear here.
Volume Reference Temperature
This section is available when a temperature-dependent density defined in a material is used. On the material frame, the density is evaluated onto a reference temperature to ensure mass conservation in the presence of temperature variations. By default the Common model input is used. This corresponds to the variable minput.Tempref, which is set by default to 293.15 K. To edit it, click the Go to Source button (), and in the Default Model Inputs node under Global Definitions, set a value for the Volume reference temperature in the Expression for remaining selection section.
The other options are User defined and all temperature variables from the physics interfaces included in the model.
This model input does not override the Reference temperature Tref set in the Physical Model section of the physics interface, and that is used to evaluate the reference enthalpy, and a reference density for incompressible nonisothermal flows.
Temperature
This section is available when temperature-dependent material properties are used. By default the temperature of the parent interface is used and the section is not editable. To edit the Temperature field, click Make All Model Inputs Editable (). The available options are User defined (default), Common model input (the minput.T variable, set to 293.15 K by default) and all temperature variables from the physics interfaces included in the model. To edit the minput.T variable, click the Go to Source button (), and in the Default Model Inputs node under Global Definitions, set a value for the Temperature in the Expression for remaining selection section.
Solid Material
This section is available only when the Local Thermal Nonequilibrium multiphysics coupling is included in the component to model porous media. It makes it possible to define different material properties for the porous matrix and the fluid.
Select any material from the list to define the Solid material. The default uses the Domain material. See Material Density in Features Defined in the Material Frame for the setting of a temperature-dependent density.
Heat Conduction, Solid
The thermal conductivity k describes the relationship between the heat flux vector q and the temperature gradient T in q = −kT, which is Fourier’s law of heat conduction. Enter this quantity as power per length and temperature.
The default Thermal conductivity k is taken From material. For User defined select Isotropic, Diagonal, Symmetric, or Full based on the characteristics of the thermal conductivity, and enter another value or expression. For Isotropic enter a scalar which will be used to define a diagonal tensor. For the other options, enter values or expressions into the editable fields of the tensor.
The components of the thermal conductivity k when given on tensor form (kxx, kyy, and so on, representing an anisotropic thermal conductivity) are available as ht.kxx, ht.kyy, and so on (using the default name ht). The single scalar mean effective thermal conductivity ht.kmean is the mean value of the diagonal elements kxx, kyy, and kzz.
Thermodynamics, Solid
This section sets the thermodynamics properties of the solid.
The heat capacity at constant pressure describes the amount of heat energy required to produce a unit temperature change in a unit mass.
The Density ρ and Heat capacity at constant pressure Cp should be specified.
In addition, the thermal diffusivity α, defined as k ⁄ (ρ Cp) (SI unit: m2/s), is also a predefined quantity. The thermal diffusivity can be interpreted as a measure of thermal inertia (heat propagates slowly where the thermal diffusivity is low, for example). The components of the thermal diffusivity α, when given on tensor form (αxx, αyy, and so on, representing an anisotropic thermal diffusivity) are available as ht.alphaTdxx, ht.alphaTdyy, and so on (using the default physics name ht). The single scalar mean thermal diffusivity ht.alphaTdMean is the mean value of the diagonal elements αxx, αyy, and αzz. The denominator ρ Cp is the effective volumetric heat capacity which is also available as a predefined quantity, ht.C_eff.
The Thermoelastic Damping subnode is available from the context menu (right-click the parent node) or from the Physics toolbar, Attributes menu.
When Surface-to-surface radiation is activated, the Opacity (Surface-to-Surface Radiation Interface) subnode is automatically added to the entire selection, with Opaque option selected. The domain selection can’t be edited. To set some part of the domain as transparent, add a new Opacity (Surface-to-Surface Radiation Interface) subnode from the context menu (right-click the parent node) or from the Physics toolbar, Attributes menu.
Heat Generation in a Disc Brake: Application Library path Heat_Transfer_Module/Thermal_Contact_and_Friction/brake_disc
Location in User Interface
Context Menus
Ribbon