ρ (SI unit: kg/m3) is the alloy’s density.
|
•
|
Cp (SI unit: J/(kg·K)) is the alloy’s heat capacity at constant pressure.
|
•
|
k (SI unit: W/(m·K)) is the alloy’s thermal conductivity (a scalar or a tensor if the thermal conductivity is anisotropic).
|
•
|
u (SI unit: m/s) is the velocity field defined by the Translational Motion subnode when parts of the model are moving in the material frame.
|
•
|
Q (SI unit: W/m3) is the heat source (or sink). Add one or several heat sources as separate physics features. See Heat Source node and Thermoelastic Damping subnode for example.
|
This model input does not override the Reference temperature Tref set in the Physical Model section of the physics interface, and that is used to evaluate the reference enthalpy, and a reference density for incompressible nonisothermal flows.
|
•
|
Volume average (default), which computes the effective conductivity of the alloy as the weighted arithmetic mean of austenite and martensite conductivities:
|
•
|
Reciprocal average, which computes the effective conductivity of the alloy as the weighted harmonic mean of austenite and martensite conductivities:
|
•
|
Power law, which computes the effective conductivity of the alloy as the weighted geometric mean of austenite and martensite conductivities:
|