By default in the Settings window for
Brinkman Equations, the
Compressibility option is set to
Weakly compressible flow. The
Density ρ in the
Porous Medium >
Fluid subnode is automatically set to the variable from the
Nonisothermal Flow multiphysics coupling feature. Other options for Compressibility are Incompressible flow or Compressible flow (Ma<0.3).
For Heat Transfer in Porous Media in the
Porous Medium >
Fluid subnode, the
Absolute pressure,
pA (
Model Input section of the
Porous Medium >
Fluid node) and the
Velocity field,
u (
Heat Convection section) are automatically set to the variables from the
Nonisothermal Flow multiphysics coupling feature.