Outlet
The Outlet node defines an edge or a part of boundary where fluid leaves the gap.
Outlet Settings
For the Outlet node with edge selection, select an Outlet conditionZero pressure, Pressure, or Normal outflow velocity.
When the Liquid with cavitation is selected in the physics interface, Starvation is also available. For Zero pressure pf = 0 applies on the edge.
For Pressure, enter a Pressure pf0 to impose pf = pf0 on the edge. If the reference pressure pref, defined at the physics interface level, is 0, pf0 is the absolute pressure. Otherwise, pf0 is the relative pressure.
For Normal outflow velocity, enter a Normal outflow velocity U0.
For Starvation, enter a value for the Fluid fraction θ0.
For the Outlet node with boundary selection, Outlet condition is set to Pressure by default. Enter a Pressure pf0 to impose pf = pf0 on the boundary.
When the Liquid with cavitation is selected in the physics interface, Starvation is also available. For Starvation, enter a value for the Fluid fraction θ0.