Inlet
Use the Inlet node to define an edge or a part of the boundary where fluid enters the gap.
Inlet Settings
For the Inlet node with edge selection, select an Inlet conditionZero pressure, Pressure, or Normal inflow velocity.
When the Liquid with cavitation is selected in the physics interface, Starvation is also available.
For Zero pressure, pf = 0 applies on the edge.
For Pressure, enter a Pressure pf0 to impose pf = pf0 on the edge. If the reference pressure pref, defined at the physics interface level, is 0, pf0 is the absolute pressure. Otherwise, pf0 is the relative pressure.
For Normal inflow velocity, enter a Normal inflow velocity U0.
For Starvation, enter a value for the Fluid fraction θ0.
For the Inlet node with boundary selection, specify the Pressure at the inlet.