The Squeeze-Film Damper node is added automatically when you set
Foundation properties to
Squeeze-Film Damper in the parent
Journal Bearing, or
Radial Roller Bearing node. In this node, you specify the damper dimensions and lubricant properties to compute the equivalent damping coefficient based on a short bearing length approximation.
Select Bulk viscosity —
From material or
User defined. If
User defined, enter the value of the
Bulk viscosity,
μ. Enter the values of
Clearance,
C,
Journal Radius,
R, and
Journal length,
L. Clear the checkbox
Include tilting (selected by default) to exclude the effect of the tilting of the journal in the damper.
This node is automatically added when Foundation Properties is set to