Initial Values
The Initial Values node adds an initial value for the electric potential and the magnetic vector potential.
Initial Values
Enter values or expressions for the initial values of the Electric potential V (SI unit: V) and the Magnetic vector potential A (SI unit: Wb/m). Note that only the z component can be specified, because the TEM-mode assumption implies that the only nonzero components of the fields are in the transverse plane.