Open Circuit
The Open Circuit boundary condition is a special case of the Terminating Impedance boundary condition, assuming an infinite impedance, and, thus, zero current at the boundary. The condition is thus
The Open Circuit boundary condition is only available on exterior boundaries.
Selected Signal Conductor Line