The Fluid node defines this version of the equation to analyze the evolution of the conversion degree during curing reactions
cr:
where
is the reaction rate, and u is the fluid velocity field, either an analytic expression or a velocity field from a Fluid Flow interface.
To specify the velocity field, select the source of the Velocity field. For
User defined, enter values or expressions for the velocity components in the input fields. This input option is always available. You can also select the velocity field solved for by a Fluid Flow interface added to the model component. These physics interfaces are available for selection in the
Velocity field list.
A diffusion factor fd is introduced to account for the reaction rate decrease as the conversion reaches the critical value. Select a
Reaction rate limiter model:
None,
Diffusion factor, and
Modified diffusion factor.