Select the Revolution per time option to manually define the rotational velocity (SI unit: rad/s) and select the Rotational direction as Positive angular velocity or Negative angular velocity. This is the default setting.
|
|
•
|
|
•
|
For Dispersed phase concentration enter a Dispersed phase volume fraction ϕd0 (dimensionless). The default is 0. When Solve for interfacial area is selected under the Physical Model section, select either the Dispersed phase number density n0 (SI unit: 1/m3) or Diameter of particles/droplets dd (SI unit: m) button and enter a value or expression for n0 (the default is 5·106 1/m3) or dd (the default is 1 mm).
|
|
•
|
For Dispersed phase flux enter values or expression for the Dispersed phase flux Nϕd (SI unit: m/s) and, if Solve for interfacial area is selected under the Physical Model section, the Number density flux Νn (SI unit: 1/(m2⋅s)). The defaults are 0 m/s and 0 1/(m2⋅s), respectively.
|
|
Dispersed Phase Boundary Condition Equations in the CFD Module User’s Guide
|