Study 3
Add Study
1
In the Home toolbar, click the Add Study
button to open the Add study window.
2
Go to the Add Study window. In the tree, under General Studies select Stationary
.
3
Click
Add Study. Then click the Add Study
in the toolbar again to close the Add study window.
Step 1: Stationary
1
In the Model Builder window under Study 3, click Step 1: Stationary
.
2
In the Settings window for Stationary locate the Study Extensions section. Select the Auxiliary sweep checkbox.
Sweep over operating temperature at constant applied pressure, to assess the temperature sensitivity of the device.
3
Click Add
.
4
In the list in the first table cell, select the parameter
T0 (Operating Temperature)
:
Parameter Name
T0
5
Click Range
. Go to the Range dialog.
-
In the Start text field, enter
290
.
-
In the Step text field, enter
5
.
-
In the Stop text field, enter
300
.
6
Click the Add button.
For this study, disable the default plots as these will be similar to those already generated by study 2.
7
In the Model Builder window, click Study 3
.
8
In the Settings window for Study locate the Study Settings section. Clear the Generate default plots checkbox.
9
Click Compute
.