Results
To aid the analysis of the results, create a series of line integrals of the heat flux across boundaries, in an Evaluation Group. Let the line integrals run across the middle section of the pipe (on the r-axis), and the contact surfaces for heat source and heat sink.
Energy Balance
1
2
In the Settings window for Evaluation Group, type Energy Balance in the Label text field.
3
4
Heat Sink
1
2
3
4
5
Heat Source
1
2
In the Settings window for Line Integration, type Heat Source in the Label text field.
3
4
Casing
1
2
3
4
Wick
1
2
3
4
Cavity
1
2
3
4
Latent heat flux from phase change
To investigate how the phase change along the wick transfers thermal energy, create a line graph plotting this heat flux along the cavity–wick boundary.
1
2
In the Settings window for 1D Plot Group, type Latent heat flux from phase change in the Label text field.
Line Graph 1
1
2
3
4
5
Locate the y-Axis Data section. In the Expression text field, type (u*spf.nr + w*spf.nz)*spf.rho*HeatOfVaporization_water21(T).
6
7
In the associated text field, type (<B>u</B>\cdot<B>n</B>)\rho\DELTA H<sub>vap</sub>.
8
9
In the Title text area, type Latent heat flux from phase change.
10
11