Study 2 - Saturated Wick
1
In the Model Builder window, click Study 2.
2
In the Settings window for Study, type
Study 2 - Saturated Wick
in the Label text field.
Material Sweep
1
In the Study toolbar, click
Material Sweep.
2
In the Settings window for Material Sweep, locate the Study Settings section.
3
Click
Add.
4
In the table, enter the following settings:
Switch
Cases
Case numbers
Fluid in wick (sw1)
User defined
2
Step 2: Stationary 1
Study 2 is solved in two steps, first without Brinkman Equations, and then with all interfaces active. Solving in this order will give the Brinkman Equations an initial guess close to the final solution, making the process more robust and efficient.
In the Model Builder window, under Study 2 - Saturated Wick right-click Step 1: Stationary and choose Duplicate.
Step 1: Stationary
1
In the Settings window for the first step in Study 2: “Step 1: Stationary”, locate the Physics and Variables Selection section.
2
In the table, clear the Solve for checkbox for Brinkman Equations (br).
3
In the Study toolbar, click
Get Initial Value.
By requesting initial values, default plot groups are created which we can now modify.