External Temperature (Thin Layer, Thin Film, Fracture)
Use this subnode to specify the temperature on the exterior side of a thin layer, a thin film, or a fracture.
Temperature
For User defined, enter a value or expression for the Temperature T0. Else, select an Ambient temperature defined in an Ambient Properties node under Definitions.
The equation for this condition is T = T0 where T0 is the external temperature to be prescribed.
Constraint Settings
To display this section, click the Show More Options button () and select Advanced Physics Options in the Show More Options dialog.
The Constraint settings can be set to Pointwise constraints (default) or Weak constraints. Select Weak constraints to replace the standard constraints with a weak implementation.
When this subnode is used with Layer type set to Thermally thin approximation, the parent thin structure feature is equivalent to the Temperature feature.
Location in User Interface
Context Menus
More locations are available. For example:
Ribbon
Physics tab with Thin Layer, Thin Film, or Fracture selected in the model tree: