The Convective Heat Transfer node is available when the
Compute grain temperature checkbox is selected in the physics interface node’s
Additional Variables section. Use the
Convective Heat Transfer node to model the heating or cooling of a grain due to convective heat exchange with the surrounding fluid, assuming surrounding fluid has no effect on the motion of grains.
The model input for the Temperature T (SI unit: K) is always shown in the settings window for this feature, even if there are no material properties that depend on it.
If Specify heat transfer coefficient is selected, enter a value or expression for the
Heat transfer coefficient h (SI unit: W/(m
2·K)). The default is
10 W/(m
2·K).
If Specify Nusselt number is selected, then by default the
Thermal conductivity k (SI unit: W/(m·K)) is taken
From material. Select
User defined from the list to enter a value or expression. The default is 0.025 W/(m·K). For this purpose, the conductivity is always assumed isotropic. Also enter a value or expression for the dimensionless
Grain Nusselt number Nu. The default value, 2, is the theoretical limit for a sphere in a fluid with zero relative velocity.