The variable Qj (SI unit: W/m
3) is the Joule heating power which is defined as
where Jc the conduction current density. The variable can be selected from a
Heat Source feature in a heat transfer interface.
The variable F (SI unit: N/m
3) is the electrohydrodynamic (EHD) force which is defined as
The variable can be selected from a Volume Force feature in a fluid flow interface.