This node is available for the Two electrodes model option. The settings of this node define the thermodynamics of the negative electrode in the battery.
Specify the Equilibrium potential and
Temperature derivative of equilibrium potential as a function of the negative degree of conversion, either
From material or
User defined. The
User defined option allows for a function name to be specified.
Specify the Equilibrium degree of conversion as a function of the initial negative electrode potential, either
From material or
User defined. The
User defined option allows for a function name to be specified. The initial negative electrode potential is defined internally based on the settings at the interface level (
Initial Cell Charge Distribution section and
State-of-Charge Definition section).
Set the Maximum and
Minimum operational potential (V) to specify the potential window of the negative electrode. These values are used together with the settings at the interface level (
Initial Cell Charge Distribution section and
State-of-Charge Definition section) to define and compute dynamic global cell variables.
This section is available only if From operational potential limits has been selected in the
State-of-Charge Definition section at the interface level.