Select Sector Symmetry at interfaces between rotating objects where sector symmetry is used. It is only available for pairs. A default subnode is added. Right-click to select additional features from the
Fallback Features submenu. In 2D, this feature assumes rotation around the origin.
To display this section, click the Show More Options button (

) and select
Advanced Physics Options in the
Show More Options dialog. The constraint setting can be set to
Pointwise constraints (default), or
Weak constraints. Additionally, the
Nitsche constraints option is available for the scalar potential in the
Electric Currents,
Magnetic Field, No Currents, and
Rotating Machinery, Magnetic interfaces. The displacement current term is excluded from the
Nitsche constraints in the
Electric Currents interface and is therefore valid in the quasistationary approximation.