Interior Wall
The
Interior Wall
node adds the boundary condition for a sound hard boundary or wall on interior boundaries. Add this node from the
Interior Conditions
submenu. The condition reads
The condition ensures that the normal velocity is zero on both the up and down side of the boundary, while applying a slit on the pressure (the pressure is discontinuous across the boundary). The condition also assumes that the background flow has a similar condition applied at the boundary.