Use the Impedance node to specify a normal specific impedance
Zn on a boundary. Add this node from the
Mechanical Conditions submenu. The condition has a user defined option as well as the option to define a simple RCL impedance model. The latter is useful for modeling the interaction with, for example, a microphone represented by a simple mass-spring-damper system.
Select the Impedance model as User defined (the default) or
RCL. For a transient model only the
User defined option exists.
Notice the matching diagram and Equation section information for each choice. Then enter the
Equivalent acoustic resistance Rac (SI unit: kg/(m
4·s)), the
Equivalent acoustic compliance Cac (SI unit: m
4·s
2/kg) and the
Equivalent acoustic inertance Lac (SI unit: kg/m
4).
Select a condition for the Tangential velocity —
Slip (perfect) (the default) or
No slip. The
No Slip option will apply an additional constraint for the velocity in the tangential direction on the boundary. When
Slip (perfect) is selected, the impedance mimics the behavior of a corresponding pressure acoustics model with a normal impedance condition.
For the RCL option this section is also visible. The impedance model is defined through an acoustic impedance (the surface area is necessary) and not a specific impedance.
For the Area select
Use symmetries or
Selected boundaries. For
Use symmetries the effective area is computed taking
Symmetry boundary conditions into account (if present). An
Area multiplication factor Ascale is automatically computed. If necessary select the
User defined option and enter a value for
Ascale. When
Selected boundaries is selected the area is computed only for the boundaries in the selection.