Use the Mapped Room Coupling node to couple two rooms when they do not share a common inner boundary. This is, for example, necessary if mid-planes have not been added in the CAD drawing. The condition has the same functionality as the Room Coupling feature except that a mapping is used between the source and destination walls.
Select the Force continuity checkbox to ensure continuity resulting in a zero transmission loss.
To display the Constraint Settings, Orientation of Source, Orientation of Destination, and Mapping Between Source and Destination sections, click the Show More Options button () and select Advanced Physics Options in the Show More Options dialog.