The Magnetic Scalar Potential Discontinuity node adds a boundary condition on an interior boundary which allows for a prescribed discontinuity in the magnetic scalar potential. The difference in magnetic scalar potential through this boundary is given by
where Vmu is the magnetic scalar potential on the upside of the boundary selection and
Vmd is the magnetic scalar potential on the downside.