Continuity (Layered Shell)
The Continuity feature is only available for the interface where the Layer Type sets to Layered Shell. Use this node to specify the side-by-side continuity conditions on the electric potential at an edge between two layered materials. By default, the electric potential is discontinuous at the interface between two layered materials.
Layer Selection
Select Source and Destination layered materials from the lists. This makes the node applicable on the edges adjacent to both selected layered materials. Click the Layer Cross Section Preview button to visualize the settings.
Constraint Settings
To display this section, click the Show More Options buttonĀ () and select Advanced Physics Options.
Connection Settings
To display this section, click the Show More Options buttonĀ () and select Advanced Physics Options. Select either Straight (default) or Twisted as the Connection type.