Body Load
Add a Body Load to boundaries (for the Plate interface add it to domains). The loads are defined in the given coordinate system.
Coordinate System Selection
The Global coordinate system is selected by default. The Coordinate system list contains all applicable coordinate systems in the model. Prescribed loads are specified along the axes of this coordinate system. See Coordinate Systems and in the COMSOL Multiphysics Reference Manual.
Force
Select the Load typeForce per reference volume, Force per deformed volume, or Total force. Enter values or expressions for fV, fv, or Ftot.
The list selection normally only contains User defined. When combining the Shell interface with another physics interface, it is also possible to select a predefined load from this list.
Moment
Select the Moment typeMoment per reference volume, Moment per deformed volume, or Total moment. Enter values or expressions for mV, mv, or Mtot.
Linear Buckling
To display this section, click the Show More Options button () and select Advanced Physics Options in the Show More Options dialog.
If you are performing a linear buckling analysis with a combination of live and dead loads, select the Treat as dead load checkbox to indicate that the load contributions from this node are constant. The default is that a load is proportional to the load factor.
 
You can add the Phase subnode to specify the phase of this load in a frequency domain analysis.
Location in User Interface
Context Menus
Ribbon
Physics tab with Shell selected:
Physics tab with Plate selected: