When this condition is applied on the boundaries of a Hygroscopic Porous Medium domain with 
Equilibrium between liquid and gas phases set to 
Nonequilibrium formulation, it also constrains the liquid saturation.
 
    The Constraint settings can be set to 
Nitsche constraints (default), 
Pointwise constraints or 
Weak constraints. The 
Nitsche constraints option ensures continuity of the diffusive flux. This option may work better than the 
Pointwise constraints or 
Weak constraints when the meshes of the source and destination boundaries do not coincide. Alternatively, select the 
Pointwise constraints option. Select 
Weak constraints to replace the standard constraints with a weak implementation.
 
    Physics tab with interface as 
Moisture Transport in Air, or any version of the Moisture Transport interface selected: