Use this node to model inflow of water vapor through a virtual domain, at inlet boundaries of moist air and hygroscopic porous medium domains. The upstream moisture conditions (either vapor concentration custr, or vapor mass fraction
ωustr, or relative humidity
ϕw,ustr and temperature
Tustr) are known at the outer boundary of the virtual domain. The inflow condition is often similar to a moisture content condition. However using this condition the upstream vapor concentration is not strictly enforced at the inlet. The higher the flow rate, the smallest difference between the inlet and upstream moisture content. In case of moisture sources or moisture constraints close to the inlet boundary, the inflow condition induces a moisture profile that approaches to the moisture profile that would be obtained by computing the solution in the virtual domain upstream the inlet.
Both the upstream vapor concentration custr, and vapor mass fraction
ωustr are defined on this boundary. Their expressions depend on the chosen inputs.
This node can be applied on the exterior boundaries of a computational domain in which either a Moist Air (Moisture Transport Interface) node, a
Hygroscopic Porous Medium node with
Equilibrium between liquid and gas phases set to
Equilibrium formulation, or a
Moist Air (Hygroscopic Porous Medium) subnode when it belongs to a
Hygroscopic Porous Medium node with
Equilibrium between liquid and gas phases set to
Nonequilibrium formulation is active. In the latter case, this node only constrains the vapor flux.
When Specify is set to
Relative humidity in the
Specify list, set both the
Upstream temperature Tustr and the
Upstream relative humidity ϕw,ustr from which the upstream vapor concentration and the vapor mass fraction can be defined:
For User Defined, enter values or expressions. Else, select any available input (like
Ambient temperature defined in an
Ambient Properties node under
Definitions).
Alternatively, choose Vapor concentration in the
Specify list, and set directly a value or expression for the
Upstream vapor concentration custr. The vapor mass fraction is then defined as
Finally, choose Vapor mass fraction in the
Specify list to set a value or expression for the
Upstream vapor mass fraction ωustr. The vapor concentration is then defined as
Physics tab with interface as
Moisture Transport in Air, or any version of the Moisture Transport interface selected:
Physics tab with Hygroscopic Porous Medium >
Moist Air selected in the model tree: