The Porosity εp (a dimensionless number between 0 and 1) uses by default the value 
From material. For 
User defined the default value is 1.
 
    Select a Permeability model to specify the capacity of the porous material to transmit flow. Depending on the 
Flow model selection in the parent 
Porous Medium feature node you can choose between the following options:
 
    The default Permeability κ (SI unit: m
2) uses the value 
From material, as defined by the 
Porous material list. For 
User defined select 
Isotropic to define a scalar value or 
Diagonal or 
Symmetric to define a tensor value.
 
    For Kozeny-Carman, enter the mean 
Particle diameter dp (SI unit: m), the default value is 0.5 mm.
 
    In case a Non-Darcian flow model is chosen in the parent node, 
Forchheimer is the default selection for the 
Permeability model. For 
Forchheimer, the default 
Permeability κ (SI unit: m
2) uses the value 
From material. Furthermore, the dimensionless 
Forchheimer parameter cF can be defined. The default value is 0.55.
 
    If Ergun is selected, enter the mean 
Particle diameter dp (default value: 0.5 mm). The permeability 
κ is then calculated using 
Equation 2-4 in the 
Porous Media Flow Module User’s Guide.
 
    A default Porous Matrix node is automatically added to the 
Porous Medium node.