The Edge Current node specifies an electric line current along one or more edges.
For the Electromagnetic Waves, Transient interface, select Edge Current Type from
User defined (the default),
Electrostatic discharge, or
Lightning. Enter pulse model parameter values and click the
Plot Pulse Shape button to inspect the edge current pulse instantly as a function of time before running a simulation.
Select Electrostatic Discharge Pulse Model —
Human body model (the default),
Extended human body model,
Machine model, or
Charged device model. Enter the values for the model parameters.
When the Electrostatic Discharge or
Lightning is used for the
Edge current type, select
Parameterized path —
Automatic (the default) or
User defined. For
User defined, specify the expression for the
Parameterized path (SI unit: m). The default is set to the built-in variable
s1. Enter an
Pulse velocity (SI unit: m/s). The default is set to the built-in constant
c_const, the speed of light. The expression for the
Parameterized path should parameterize the edge where the
Edge Current is applied. Select the
Reverse direction check box as needed to reverse the direction of the current.