The Diffuse Flux boundary condition sets the molecular flux emitted from the boundary to a user-specified value. This boundary condition applies only in the molecular flow limit (Knudsen number, Kn
> 10). The flux is emitted according to Knudsen’s law (the emitted flux in a given direction is proportional to the cosine of its angle to the surface normal). This can be set directly as a flux, as a total incoming mass flow, or as number of SCCMs. The flux is assumed to be emitted from a stationary boundary.
For Directly enter a value or expression for the
Molecular flux Jo (SI unit: 1/(m
2·s)). The default is 0 (1/(m
2·s)).
For Number of SCCM units enter the
Number of SCCM units Qsccm (dimensionless), and this quantity is automatically converted to a standardized volumetric flow rate in SI units. Select an option from the
Standard flow rate defined by list —
Standard density (the default) or
Standard pressure and temperature.
For Mass flux enter a value or expression for the
Mass flux Mf (SI unit: kg/(m
2·s)).
For Total mass flow enter a value or expression for the
Total mass flow Qm (SI unit: kg/s).