Use the Slip Wall node to specify a wall with slip adjacent to a solid region in which the heat transfer equations are solved. A wall velocity can be specified along with the slip coefficients.
Enter the components for the Velocity of moving wall uw. Select the
Slip coefficients:
Maxwell’s model (the default) or
User defined. These settings are the same as for
External Slip Wall.