Electromagnetic Models
These material property groups for various electromagnetic material models (including their associated physical properties) can be added to models from the
Material
window. These property groups are used by the AC/DC Module, RF Module, and Wave Optics Module.
Table 9-13:
Electromagnetic Models Materials.
Property Group and Property
Name/Variable
SI Unit
B-H Curve
This material node is only available with the AC/DC Module.
Local Properties
normH
-
Magnetic flux density norm
normB
T
Dielectric Losses
Dielectric loss factor
eta_epsilon
-
Relative permittivity (imaginary part)
epsilonBis
1
Relative permittivity (real part)
epsilonPrim
1
E-J Characteristic
This material node is only available with the AC/DC Module.
Electric field norm
normE
V/M
Local Properties
normJ
-
Effective B
-
H Curve
This material node is only available with the AC/DC Module.
Local Properties
normHeff
-
Magnetic flux density norm
normBeff
T
Jiles–Atherton Model Parameters
This material node is only available with the AC/DC Module.
Maximum magnetization parameter
MsJA (3x3 matrix)
A/m
Langevin slope parameter
aJA (3x3 matrix)
A/m
Pinning parameter
kJA (3x3 matrix)
A/m
Reversibility parameter
cJA (3x3 matrix)
1
Interdomain coupling parameter
alphaJA (3x3 matrix)
1
Linearized Resistivity
This material node defines the electric resistivity (and conductivity) as a linear function of temperature.
Reference resistivity
rho0
Ω
·m
Reference temperature
Tref
K
Resistivity temperature coefficient
alpha
1/K
Loss Tangent, loss angle
This material node assumes zero conductivity.
Loss tangent, loss angle
delta
rad
Relative permittivity (real part)
epsilonPrim
1
Loss Tangent, Dissipation Factor
This material node assumes zero conductivity.
Loss tangent, dissipation factor
tanDelta
1
Relative permittivity (real part)
epsilonPrim
1
Magnetic Losses
Relative permeability (imaginary part)
murBis
-
Relative permeability (real part)
murPrim
-
Refractive Index
This material node assumes a relative permeability of unity and zero conductivity. This material node is only available with the RF Module or the Wave Optics Module.
Refractive index, imaginary part
ki
-
Refractive index
n
1
Remanent flux density
This material node is only available with the AC/DC Module.
Recoil permeability
murec
1
Remanent flux density norm
normBr
T