ReflectionGraph, ImpedanceGraph, AdmittanceGraph
Create a reflection graph, impedance graph, or admittance graph in a Smith plot. You can add a Reflection Graph, Impedance Graph, and Admittance Graph to a SmithGroup.
Syntax
model.result(<pgtag>).create(<ftag>,"ReflectionGraph");
model.result(<pgtag>).create(<ftag>,"ImpedanceGraph");
model.result(<pgtag>).create(<ftag>,"AdmittanceGraph");
model.result(<pgtag>).feature(<ftag>).set(property,<value>);
model.result(<pgtag>).feature(<ftag>).run();
Description
The reflection graph, impedance graph, and admittance graph are all graphs that appear in a Smith plot. The expressions to use can be S-parameters from an RF simulation, for example. For an impedance plot you can also provide a reference impedance; for an admittance plot you can also provide a reference admittance.
The following properties are available:
true | false
true | false
true | false
true | false
true | false
default | long
The color cycle, when linecolor is set to cycle. With default, it contains 7 colors; with long, it contains 19 colors.
{0,0,1} or last used edgecolor
none | parent | dataset name
The description of the expressions in expr. Is used in the automatic legends.
on | off
on | off
linpoint | harmonic | lintotal | lintotalavg | lintotalrms | lintotalpeak
on | off
all | first | last | manual | manualindices | interp
How to input the solution to use. manual indicates that solnum is used. manualindices indicates that solnumindices is used. interp indicates that t is used.
The times to use, for transient levels. Available when data is not parent and the underlying data is transient.
on | off
The precision for the evaluated expression when legendmethod is set to evaluated.
automatic | manual | evaluated
A legend string to be evaluated when legendmethod is set to evaluated.
Manual legends active when legendmethod is set to manual.
custom | cycle | black | blue | cyan | gray | green | magenta | red | white | yellow
double | preference
none | cycle | asterisk | circle | diamond | plus | point | square | star | triangle
none | cycle | solid | dotted | dashed | dashdot
An alternative way to specify the solutions to use, allowing you to enter, for example, range(1,1,20). Applicable when looplevelinput is manualindices on a level.
String array with all | first | last | manual | manualindices | interp on each level
all on all levels
How to input the solution to use, per level. manual on a level indicates that looplevel is used on that level. manualindices on a level indicates that looplevelindices is used on that level. interp on a level indicates that interp is used on that level.
interp | datapoints
all | first | last | manual | manualindices
How to input the outer solutions to use. Applicable only for parametric sweep models. manual indicates that outersolnum is used. manualindices indicates that outersolnumindices is used.
The solutions to plot. Available when data is not parent and the underlying data has multiple solutions.
An alternative way to specify the solutions to use, allowing you to enter, for example, range(1,1,20). Applicable when innerinput is manualindices.
solnum | solutioninfo
manual | parent
If data is a local dataset with nontrivial data, specify solutions manually or take them from the parent plot group.
The times to plot. Available when data is not parent and the underlying solution is transient.
The title to use when titletype is manual.
auto | custom | label | manual | none
auto, if the title should be computed automatically. custom, if the title should be computed automatically, but customized. label, if the title should be the plot group’s label. manual, if the manual title should be used (the title property). none, if no title should be displayed.
on | off
The unit to use for the expression in expr. If the old unit is not valid when the expression changes, the unit property is reset to default.
on | off
Attributes
Color, Filter (Plot Attribute)
See Also
SmithGroup