If the Level Set Model node is a domain feature under the
The Level Set Interface, it adds the following transport equation governing a level set function
ϕ:
In both cases the Level Set Model node provides the options to define the associated level set parameters and the velocity field.
Enter a value or expression for the Reinitialization parameter γ (SI unit: m/s). The default is 1 m/s.
Enter a value or expression for the Parameter controlling interface thickness εls (SI unit: m). The default expression is
ls.ep_default, a value proportional to the maximum element size with a proportionality factor dependent on the ratio of the maximum and minimum element sizes in the domain.
Enter values or expressions for the components (u,
v, and
w in 3D, for example) of the
Velocity field u (SI unit: m/s). The applied velocity field transports the level set function through convection.