Specify turbulent length scale and intensity defines the turbulence inlet conditions using the Turbulent intensity IT,c (dimensionless) and the Turbulence length scale LT,c (SI unit: m).
|
•
|
Specify turbulence variables prescribes the Turbulent kinetic energy k0,c (SI unit: m2/s2) and the Turbulent dissipation rate ε0,c (SI unit: m2/s3) at the inlet.
|
•
|
For Volume fraction, specify the Dispersed phase volume fraction, ϕd0, at the inlet. This option locks the value of ϕd, but the exact flux depends on the dispersed phase velocity, ud0.
|
•
|
For Mass flux, prescribe describe the Inward dispersed phase mass flux, (SI unit: kg/(m2·s)). This option prescribes the flux for the dispersed phase, but the resulting volume fraction at the inlet depends on the dispersed phase velocity, ud0.
|
•
|
Specify turbulent length scale and intensity defines the turbulence inlet conditions using the Turbulent intensity IT,d (dimensionless) and the Turbulence length scale LT,d (SI unit: m).
|
•
|
Specify turbulence variables prescribes the Turbulent kinetic energy k0,d (SI unit: m2/s2) and the Turbulent dissipation rate ε0,d (SI unit: m2/s3) at the inlet.
|
•
|
Specify turbulent length scale and intensity defines the turbulence inlet conditions using the Turbulent intensity IT (dimensionless) and the Turbulence length scale LT (SI unit: m).
|
•
|
Specify turbulence variables prescribes the Turbulent kinetic energy k0 (SI unit: m2/s2) and the Turbulent dissipation rate ε0 (SI unit: m2/s3) at the inlet.
|