For the initial search for a feature it is good practice to use a tolerance slightly higher than the default import tolerance, 10-5 m. Thus, in a first attempt, search for small faces with a maximum size of 10
-4 m. Continue by deleting all or some of the returned small faces, then search again with an even higher tolerance, for example 5·10
-4 m.