in the homogeneous domain exterior to a closed surface, S,
 can be explicitly expressed in terms of the values of  
p and its normal derivative on 
S:
 
    Here the coordinate vector r parameterizes 
S. The unit vector 
n is the outward normal to the exterior infinite domain; thus, 
n points 
into  the domain that 
S encloses. The function 
G (R, r) is a Green’s function satisfying
 
    This essentially means that the Green’s function, seen as a function of  r, is an outgoing traveling wave excited by a simple source at 
R. In 3D, the Green’s function is therefore:
 
    The default in the Exterior Field Calculation feature is to evaluate the full Helmholtz-Kirchhoff integral given in 
Equation 2-23 and 
Equation 2-24.
 
    Taking the limit of Equation 2-23 when 
| R | goes to infinity and ignoring the rapidly oscillating phase factor, the far field, 
pfar is defined as
 
    In this integral, r and 
z are the radial and axial components of 
r, while 
R and 
Z are the radial and axial components of 
R.
 
    To evaluate the pressure in the far-field limit according to the equations in this section, set the Type of integral option to the 
Far-field integral approximation for r → ∞ option in the 
Exterior Field Calculation section in the 
Settings window for the feature. See 