The Convected Acoustic–Structure Boundary, Time Explicit multiphysics coupling (
) is used to couple the
Convected Wave Equation, Time Explicit with the
Elastic Waves, Time Explicit interface. The condition is added on the boundary between the fluid domain and the solid domain for modeling acoustic structure interaction (ASI) or vibroacoustic problems in the presence of a stationary background flow. The condition is applicable for physically correct configurations, specifically where the normal component of the background flow is zero,
n · u0 = 0.
If possible, the Pair Convected Acoustic–Structure Boundary, Time Explicit condition should be used as it will improve the performance of the time explicit method.
See Settings for further details about
Label and
Name.
The default Name (for the first multiphysics coupling feature in the model) is
csbte1.