Normal Flow
The Normal Flow node implies that the flow is normal to the boundary and thus that the tangential velocity is zero. This corresponds to a constant velocity potential along the boundary. Because the velocity potential is determined only up to a constant, imposing this condition fixes the arbitrary constant to zero where ϕ = 0.
Setting the Normal Flow condition on two or more disjoint boundaries can result in the wrong features unless symmetry implies that the velocity potential is equal on the boundaries in question. In general, only one unique flow origin or inlet can be set up.