Calculating Lumped Parameters Using the Energy Method
When using this method the potential or the current is nonzero on one or two terminals at a time and the energy density is extracted and integrated over the whole geometry. The following formulas show how to calculate the capacitance matrix from the integral of the electric energy density.
Calculate the inductance matrix in the same way from the magnetic energy density:
This is the technique used when
Fixed current
is selected.