Use the Thin Low Permeability Gap boundary condition to model gaps in magnetic materials filled with another material with smaller relative permeability. This feature applies the condition
The default Relative permeability μr (dimensionless) is taken
From material. For
User defined select
Isotropic,
Diagonal,
Symmetric, or
Full based on the characteristics of the relative permeability, and then enter a value or expression in the field or matrix.
Enter a Surface thickness ds (SI unit: m) for the gap. The default is 1 m.