2
|
Go to the Settings window for Boundary Mode Analysis locate the Study Settings section and enter 1 in the Desired number of modes text field.
|
3
|
In the Search for modes around text field enter the largest effective mode index, 3.4716716315032126. You can select the value in your text editor and then copy and paste it here. The last figures could be different from what is written here.
|
2
|
In the Settings window for Boundary Mode Analysis locate the Study Settings section. In the Search for modes around text field enter (or copy and paste) 3.4714218110358384. This should be the third largest effective index. The last figures could be different from what is written here.
|
3
|
Enter 2 in the Port name text field.
|
3
|
2
|
Go to the Settings window for Boundary Mode Analysis locate the Study Settings section and enter 4 in the Port name text field.
|
2
|
Go to the Settings window for Frequency Domain locate the Study Settings section and enter f0 in the Frequencies text field.
|