Thermal Expansion (Attachment)
Add the Thermal Expansion subnode to prescribe a deformation of the attachment caused by changes in temperature. This makes it possible to reduce stresses caused by the attachment being rigid, while there are thermal deformations in the flexible body to which it is attached.
[Select an Input type to specify how the thermal strain is entered. The default is Secant coefficient of thermal expansion, in which case the thermal strain is given by
here, the secant coefficient of thermal expansion α can be temperature dependent.
When Input type is Tangent coefficient of thermal expansion, the thermal strain is given by
where αt is the tangential coefficient of thermal expansion.
When Input type is Thermal strain, enter the thermal strain dL as function of temperature explicitly.
In all three cases, the default is to take values From material. When entering data as User defined, select Isotropic, Diagonal, or Symmetric to enter one or more components for a general coefficient of the thermal expansion tensor or the thermal strain tensor. When a nonisotropic input is used, the axis orientations are given by the coordinate system selection in the parent node.
Thermal Expansion Properties
Specify the thermal properties that define the thermal strain in the attachment.
Select Inherit from domain to take the thermal expansion data from the domain to which it is attached. This should only be used when:
When Inherit from domain is not selected, enter:
A value or expression for the Volume reference temperature Tref that is the temperature at which there are no thermal displacements at the constraints.
A value or expression for Temperature T, specifying the temperature distribution of the surrounding material. Any temperature variation must be an explicit function of the material frame coordinates. It is not possible to use a computed temperature distribution.
Select the Input typeSecant coefficient of thermal expansion, Tangent coefficient of thermal expansion, or Thermal strain to specify how the thermal strain is entered. The default values From material are used. This requires that a material has been assigned to the boundaries, edges, or points where the constraint is active. When a nonisotropic coefficient of thermal expansion is used, the axis orientations are given by the coordinate system selected in the Coordinate System Selection section.
Enter the coordinates of the Reference point, the point where the displacement is zero. The choice of reference point only affects the rigid body motion. If there are several different constraints with a Thermal Expansion subnode, the same reference point should usually be selected in all of them.
Location in User Interface
Context Menus
Ribbon
Physics tab with Attachment node selected in the model tree: