External Temperature (Thin Layer, Thin Film, Fracture)
Use this subnode to specify the temperature on the exterior side of a thin layer, a thin film, or a fracture, when
Layer type
is set to
Thermally thick approximation
or
General
, on exterior boundaries.
Temperature
For
User defined
, enter a value or expression for the
Temperature
T
0
. Else, select an
Ambient temperature
defined in an
Ambient Properties
node under
Definitions
.
The equation for this condition is
T
=
T
0
where
T
0
is the external temperature to be prescribed.
Constraint Settings
To display this section, click the
Show More Options
button (
) and select
Advanced Physics Options
.
You can specify a harmonic variation of the temperature value in a frequency domain analysis of perturbation type, by adding a
Harmonic Perturbation
subnode. See
Theory for Harmonic Heat Transfer
for more details.
•
Thin Layer (Heat Transfer Interface) and Solid (Heat Transfer in Shells Interface)
•
Thin Film (Heat Transfer Interface) and Fluid (Heat Transfer in Shells Interface)
•
Theory for Heat Transfer in Thin Structures
Location in User Interface
Context Menus
Heat Transfer in Solids>Thin Layer>External Temperature
Heat Transfer in Solids>Thin Film>External Temperature
Heat Transfer in Solids>Fracture>External Temperature
More locations are available. For example:
Heat Transfer in Fluids>Thin Layer>External Temperature
Ribbon
Physics tab with
Thin Layer
,
Thin Film
, or
Fracture
selected in the model tree:
Attributes>External Temperature