The Line Mass Source feature models mass flow originating from a tube or line region with an infinitely small radius.
The Line Mass Source feature is available for all dimensions, but the applicable selection differs between the dimensions.
Enter the source strength, , for each species (SI unit: mol/(m·s)). A positive value results in species injection from the line into the computational domain, and a negative value means that the species is removed from the computational domain.